2
Product & Equipment Quickfinder
Reset All
sectionNumber
Power Solution
13261
Industrial
13361
Mobile
12344
Portable
230 kW
Enclosures / 230REOZJE
Return to Results

Features
- KOHLER Co. provides one-source responsibility for the generating system and accessories.
- The generator set and its components are prototype-tested, factory-built, and production-tested.
- The 60 Hz generator set offers a UL 2200 listing.
- The generator set accepts rated load in one step.
- The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards.
- The generator set complies with ISO 8528-5, Class G2, requirements for transient performance in all generator set configurations. Select the Decision-Maker(R) 550 controller for improved voltage regulation and ISO 8528-5, Class G3, compliance.
- The 60 Hz generator set engine is certified by the Environmental Protection Agency (EPA) to conform to Tier 3 nonroad emissions regulations.
- A one-year limited warranty covers all systems and components. Two-, five-, and ten-year extended warranties are also available.
Alternator features:
- KOHLER's unique Fast-Response(TM) II excitation system delivers excellent voltage response and short circuit capability using a permanent magnet (PM)-excited alternator.
- The brushless, rotating-field alternator has broad range reconnectability.
- NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting.
- Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds.
- Sustained short-circuit current enabling down stream circuit breakers to trip without collapsing the alternator field.
- Self-ventilated and drip-proof construction.
- Vacuum-impregnated windings with fungus-resistant epoxy varnish for dependability and long life.
- Superior voltage waveform from a two-thirds pitch stator and skewed rotor.
- Fast-Response(TM) II brushless alternator with brushless exciter for excellent load response.
Other features:
- Controllers are available for all applications.
- The low coolant level shutdown prevents overheating (standard on radiator models only).
- Integral vibration isolation eliminates the need for under-unit vibration spring isolators.


Specifications
Prime Ratings: | ![]() |
205 kW (256 kVa) |
![]() |
||
Standby Ratings: | ![]() |
230 kW (288 kVa) |
![]() |
||
Hertz: | ![]() |
60 Hz |
![]() |
||
Alternator Type: | ![]() |
Brushless, Permanent-Magnet |
![]() |
||
Generator weights and dimensions | ![]() |
|
Length: | ![]() |
3000 (118.1) |
Width: | ![]() |
1300 (51.2) |
Height: | ![]() |
1891 (74.4) |
Weight, wet: | ![]() |
2268 (5001) |
![]() |
||
EPA Tier Level: | ![]() |
3 |
![]() |
||
Engine Manufacturer: | ![]() |
John Deere |
![]() |
||
Engine Model: | ![]() |
6090HF484C |
![]() |
||
Cylinder Arrangement: | ![]() |
6 Inline |
![]() |
||
Engine RPM: | ![]() |
1800RPM |
![]() |
||
Max Power at Rated RPM: | ![]() |
258 kWm (346 BHP) |
![]() |
||
Prime Fuel Consumption at | ![]() |
|
100% load: | ![]() |
53.3 Lph (14.1 gph) |
75% load: | ![]() |
40.9 Lph (10.8 gph) |
50% load: | ![]() |
29.2 Lph (7.7 gph) |
25% load: | ![]() |
17.4 Lph (4.6 gph) |
![]() |
||
Standby Fuel Consumption at | ![]() |
|
100% load: | ![]() |
61 Lph (16.1 gph) |
75% load: | ![]() |
46.8 Lph (12.4 gph) |
50% load: | ![]() |
33.1 Lph (8.7 gph) |
25% load: | ![]() |
19.7 Lph (5.2 gph) |
![]() |