2
Product & Equipment Quickfinder
Reset All
sectionNumber
Power Solution
13261
Industrial
13361
Mobile
12344
Portable
48 kW
Enclosures / 48REOZK4


Features
- KOHLER Co. provides one-source responsibility for the generating system and accessories.
- The generator set and its components are prototype-tested, factory-built, and production-tested.
- The 60 Hz generator set offers a UL 2200 listing.
- The generator set accepts rated load in one step.
- The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards.
- A one-year limited warranty covers all systems and components. Two- and five-year extended limited warranties are also available.
Alternator features:
- NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting.
- Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds.
- Sustained short-circuit current enabling down stream circuit breakers to trip without collapsing the alternator field.
- Self-ventilated and drip-proof construction.
- Windings are vacuum-impregnated with epoxy varnish for dependability and long life.
- Superior voltage waveform from a two-thirds pitch stator and skewed rotor.
Engine features:
- Uses cooled Exhaust Gas Regeneration (EGR) and Diesel Oxidation Catalyst (DOC) to meet Tier 4 Final without a Diesel Particulate Filter (DPF).
- Heavy-duty air cleaner with air restriction indicator.
- Lockable battery disconnect switch.
Other features:
- Kohler designed controller for guaranteed system integration and remote communication.
- The low coolant level shutdown prevents overheating.
- Durable steel, sound-attenuating housing with quiet operation of 69 dB(A) @ 7 m (23 ft.) with full load at prime rating.
- Stainless steel hinges and lockable latches on doors.
- 125% environmental containment basin for oil and coolant.


Specifications
Prime Ratings: | ![]() |
43 kW (53 kVa) |
![]() |
||
Standby Ratings: | ![]() |
48 kW (60 kVa) |
![]() |
||
Hertz: | ![]() |
60 Hz |
![]() |
||
Alternator Type: | ![]() |
4-Pole, Rotating-Field, Brushless, Permanent-Magnet |
![]() |
||
Generator weights and dimensions | ![]() |
|
Length: | ![]() |
2504 (98.6) |
Width: | ![]() |
1120 (44.1) |
Height: | ![]() |
1895 (74.6) |
Weight, wet: | ![]() |
1989 (4385) |
![]() |
||
EPA Tier Level: | ![]() |
4 Final |
![]() |
||
Engine Manufacturer: | ![]() |
Kohler |
![]() |
||
Engine Model: | ![]() |
KDI 3404 TCR |
![]() |
||
Cylinder Arrangement: | ![]() |
4 Inline |
![]() |
||
Engine RPM: | ![]() |
1800RPM |
![]() |
||
Max Power at Rated RPM: | ![]() |
55.4 kWm (74.3 BHP) |
![]() |
||
Fuel Capacity in Gallons: | ![]() |
102 |
![]() |
||
Prime Fuel Consumption at | ![]() |
|
100% load: | ![]() |
12.9 Lph (3.4 gph) |
75% load: | ![]() |
9.5 Lph (2.5 gph) |
50% load: | ![]() |
6.4 Lph (1.7 gph) |
25% load: | ![]() |
3.2 Lph (0.8 gph) |
![]() |
||
Standby Fuel Consumption at | ![]() |
|
100% load: | ![]() |
3.8 Lph (14.2 gph) |
75% load: | ![]() |
2.9 Lph (10.9 gph) |
50% load: | ![]() |
2.0 Lph (7.7 gph) |
25% load: | ![]() |
1.2 Lph (4.6 gph) |
![]() |